18 for more information please phone 01638 665161 continued on next page sf 2010 sf 2012 general purpose iec inlet filter with integral single or double fuseholder. sf 2010 rated leakage current inductance connections resistor number approvals sf 2012 current a @ 250v 50hz l1 mh l2 h input output value m ? of fuses standard version sf 2010-2/01 2 0.2ma 2.0 iec 320 6.3 x 0.8 faston 1 1 sf 2012-2/01 2 0.2ma 2.0 iec 320 6.3 x 0.8 faston 1 2 sf 2010-6/01 6 0.2ma 0.5 iec 320 6.3 x 0.8 faston 1 1 sf 2012-6/01 6 0.2ma 0.5 iec 320 6.3 x 0.8 faston 1 2 medical version sf 2010m-2/01 2 5 a 2.0 iec 320 6.3 x 0.8 faston 1 1 sf 2012m-2/01 2 5 a 2.0 iec 320 6.3 x 0.8 faston 1 2 sf 2010m-6/01 6 5 a 0.5 iec 320 6.3 x 0.8 faston 1 1 sf 2012m-6/01 6 5 a 0.5 iec 320 6.3 x 0.8 faston 1 2 surge protected version (iec 950 not applicable) sf 2010z-2/01 2 0.2ma 2.0 iec 320 6.3 x 0.8 faston 1 1 sf 2012z-2/01 2 0.2ma 2.0 iec 320 6.3 x 0.8 faston 1 2 sf 2010z-6/01 6 0.2ma 0.5 iec 320 6.3 x 0.8 faston 1 1 sf 2012z-6/01 6 0.2ma 0.5 iec 320 6.3 x 0.8 faston 1 2 earth line choke version sf 2010e-2/01 2 0.2ma 2.0 300 iec 320 6.3 x 0.8 faston 1 1 sf 2012e-2/01 2 0.2ma 2.0 300 iec 320 6.3 x 0.8 faston 1 2 sf 2010e-6/01 6 0.2ma 0.5 300 iec 320 6.3 x 0.8 faston 1 1 sf 2012e-6/01 6 0.2ma 0.5 300 iec 320 6.3 x 0.8 faston 1 2 earth line choke, surge protected (iec 950 not applicable) sf 2010ez-2/01 2 0.2ma 2.0 300 iec 320 6.3 x 0.8 faston 1 1 sf 2012ez-2/01 2 0.2ma 2.0 300 iec 320 6.3 x 0.8 faston 1 2 sf 2010ez-6/01 6 0.2ma 0.5 300 iec 320 6.3 x 0.8 faston 1 1 sf 2012ez-6/01 6 0.2ma 0.5 300 iec 320 6.3 x 0.8 faston 1 2 .15 .4 1 4 10 40 100 500 frequency mhz db 90 80 70 60 50 40 30 20 10 .1 .15 .4 1 4 10 40 100 500 frequency mhz db 90 80 70 60 50 40 30 20 10 .1 .15 .4 1 4 10 40 100 500 frequency mhz db 90 80 70 60 50 40 30 20 10 .1 2 & 6 amp standard & surge prot 2 & 6 amp earth line choke & earth`line choke surge protected 2 & 6 amp medical version approved ? submitted for approval temperature range : -25 0 c to +85 0 c operating voltage : 250vac operating frequency : 0 to 400hz test voltage : l+n to ground, 2700vdc, 2 seconds asymmetric symmetric asymmetric symmetric asymmetric symmetric iec 950 (en 60950) applications twin fused version only varistor zinc oxide type; energy absorption 21 joules (current impulse defined in iec 60-2 section 6). varistor voltage: 430vdc(measured at 1ma); clamping voltage 710v at 10a
19 for more information please phone 01638 665161 sf 2010 sf 2012 dimensions all dimensions are nominal and in mm circuit diagrams sf 2010 = 1 fuse 5 x 20mm sf 2012 = 2 fuses 5 x 20mm 41 57 33.2 46 28.7 36 36 n l1 l1 line load e r l n e l 2x2,200pf (y) 0.015f (x2) n l1 l1 line load e r l n e l 0.015f (x2) 0.015f (x2) n l1 l1 l2 line load e r l n e l 2x2,200pf (y) 0.015f (x2) n l1 l1 line load e r l n e l 2x2,200pf (y) 0.015f (x2) n l1 l1 l2 line load e r l n e l 2x2,200pf (y) 0.015f (x2) continued from previous page standard version surge protected version (suffix z ) earth line version (suffix e ) medical version (suffix m ) earth line choke, surge protected version (suffix ez ) 36 panel cut out front and rear mounting 3.6 r3.0 29.0 33.5
|